| Disconnect the fuel feed lines at the quick couplings from the fuel filter -1-. To do so, push the quick couplings onto the nozzles, press in the securing elements (hold pressed) and detach the quick couplings. |
–
| Unclip the fuel filter -1- from the bracket. |
–
| Remove fuel filter from the top. |
Installation is carried out in the reverse order. Pay attention to the following: |
t
| Pay attention to the fitting position of the fuel filter. The arrows engraved on the filter identify the fuel inlet and the fuel outlet. |
t
| Lay the fuel hoses avoiding any kinks. |
t
| Make sure the quick couplings fit tightly. Check for secure catch by tightening it in the opposite direction. |
–
| Filling and bleeding the fuel system. For this purpose, connect vehicle diagnosis, measurement and information system -VAS 505X- and carry out the targeted function „filling/bleeding the high pressure pump and the fuel system“. During this function, the fuel pump is actuated for 180 seconds. |
|
|
|