Specified value display field 4: |
Note The abbreviation “ADP” in display field 4 stands for “Adaption”, which in fact means adaptation. |
If the adaptation is aborted by the control unit, this may be due to the following reasons: |
t
| The throttle valve cannot be fully closed (e.g. dirt). |
t
| The battery voltage is too low. |
t
| The engine is started during the adaptation or the accelerator pedal is pressed. |
t
| Warping of the throttle valve housing (check screwed connection). |
t
| After the abortion the tester displays “function unknown or cannot be performed”. When the ignition is switched on again (a few seconds) the adaptation is automatically performed again. |
–
| End the basic setting of the engine by pressing →. |
|
|
System in basic setting 60 | 10.5 % 89.0 % 0 ADP o.k. |
|