| Connect test box -V.A.G 1598/22 - to the connector of the control unit. |
–
| Check wiring between the test box and the plug for open circuit according to the current flow diagram. |
| Cable resistance: max. 1.5°Ω |
–
| Also test the wires in the plug for short circuit to each other. |
If no fault was detected in the wiring and if there was no voltage between contact 1 + 3: |
If no fault was detected in the wiring and if there was no voltage between contact 1 + 3: |
–
| Replace 1AV control unit - J382- → Chapter. |
|
|
|