| Hold the fuel feed line -1- (lengthened with a suitable hose -2-) in a measuring vessel -3-. |
–
| Connect vehicle diagnosis, measurement and information system -VAS 505x- and carry out the function „test fuel pump“. |
Note The fuel pump is actuated for 30 seconds. |
l
| Specified value of minimum flow rate in 30 seconds: min. 600 ml |
If the minimum flow rate is not reached, the following faults may be present: |
t
| Battery voltage too low. |
t
| Fuel lines crimped, carry out a visual inspection. |
t
| The fuel filter is clogged. |
t
| There is a leak in the fuel system, check for tightness. |
Special tools and workshop equipment required |
t
| Remote control, e.g. -V.A.G 1348/3A- |
t
| Measuring tool set, e.g. -V.A.G 1594C- |
t
| Adapter, e.g. -V.A.G 1318/16- |
t
| Adapter, e.g. -V.A.G 1318/17- |
l
| Battery voltage at least 12 V. |
l
| Fuel temperature 15…30 °C. |
l
| Fuel tank must be at least 1/4 full. |
Note t
| Safety precautions when working on the fuel supply system → Chapter. |
–
| Unscrew the cap from the fuel filler neck. |
Vehicles Octavia II and Superb II |
–
| Remove floor covering under the rear seat bench. |
Continued for all vehicles |
|
|
|