| Remove evaporator -A- from the evaporator housing bottom part. |
Note t
| Before inserting the evaporator, check the condensation water drain and the evaporator housing, if necessary clean (if required also the evaporator). |
t
| Check seal -F- (it must be sealed all around). |
–
| Fit holder -C- and seal/insulation -B- onto the pipe connections of the evaporator -D- and -E-. |
–
| Insert evaporator -A- into the evaporator housing bottom part as shown in the fig. |
–
| When inserting the evaporator -A- into the evaporator housing bottom part and when assembling both housing parts, ensure that the seal -F- is not damaged. |
Note t
| After assembling the housing halves, make sure that the seal/insulation -B - is correctly fitted in the opening for the access to both coolant pipes. |
t
| Check that the holder -C- is correctly fitted on both coolant pipes -D- and -E-. If the heat-protection insulation -B- is missing or not correctly installed, it may result in a power reduction of the air conditiong system (tuning modification of the regulator characteristic of the expansion valve due to heat radiation). |
t
| There is refrigerant oil in the removed evaporator which must be guided back with the new evaporator into the refrigerant circuit → Chapter. |
|
|
|