suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

EVAP Leak Check Module and Its Circuit Inspection (Vehicle With ORVR System)|Page 2213 > < EVAP Leak Check Module and Its Circuit Inspection (Vehicle With ORVR System)|Page 2211
Page 4
background image

2. Reference vacuum pressure (reference orifice vacuum) check:

a. In the state of Step 1), operate EVAP leak detection pump by connecting 12 V -battery to terminal "1" and terminal "5" of EVAP leak check

module. Under pump operating, check that pressure sensor output voltage (reference orifice vacuum) becomes lower than pressure sensor
output voltage) of step 1) by approx. 0.1 V.
If sensor voltage is out of specification, replace EVAP leak check module.

EVAP Leak Check Module Visual Check

Reference: EVAP Canister Removal and Installation

Check EVAP leak check module and its O-ring (1) for damage and deterioration. If malfunctioning is found, replace.

EVAP Leak Check Module and Its Circuit Inspection (Vehicle With ORVR System)|Page 2213 > < EVAP Leak Check Module and Its Circuit Inspection (Vehicle With ORVR System)|Page 2211