Aerio L4-2.3L (2006)
6. Disconnect side sensor connector sliding connector outer (1) as shown.
Installation
CAUTION: Proper operation of side sensor requires sensor be rigidly attached to specified position.
1. Check that none of following faulty conditions exists.
-
Bend, deformity or rust of under body.
-
Foreign matter on mating surface of sensor.
2. Install side sensor (1) on under body (2) and tighten side sensor bolt (3) to specified torque.
Tightening torque
Side sensor bolt a: 9 N.m (0.9 kg-m, 6.5 lb-ft)