suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Evaporator Case|Removal|Page 2645 > < Evaporator Case|Testing and Inspection
Page 1
background image

Evaporator Case: Service and Repair
Removal

EVAPORATOR (COOLING UNIT)

1. Disconnect negative (-) cable at battery.
2. Disable air bag system. 
3. Recover refrigerant by using recovery and recycling equipment. Be sure to follow the instruction manual for the equipment.

The amount of compressor oil removed must be measured and the same amount added to the system.

4. Disconnect blower motor and resister wire couplers.
5. Disconnect fresh air control cable from blower motor unit.
6. Remove blower motor unit after removing glove box and ECM.
7. Disconnect A/C amplifier and thermistor wire couplers.
8. Disconnect compressor suction pipe, receiver/dryer outlet pipe and drain hose from evaporator (cooling unit).

NOTE:  As soon as above hose and pipe are disconnected, cap opened fittings so that moisture and dust may not enter cooling unit.

9. Remove evaporator with evaporator case.

10. Remove A/C amplifier from lower case.