following specification.
If measure voltage is out of specification or does not vary linearly as the shown in graph, check related wire circuit and HVAC control module. If
wire circuits and HVAC control module are OK, go to next step.

Temperature control actuator output voltage
0.48 - 4.53V (linear variation as given graph)

7. Set temperature selector of HVAC control module to "MAX HOT" position with ignition switch turned ON, and make sure if the position of

actuator lever is  "MAX HOT"  position (A).

8. Turn ignition switch to OFF position, and then disconnect connector from temperature control actuator.
9. Measure resistance between terminal "1" and "2".

Temperature control actuator resistance between terminal "1" and "2" (MAX HOT position) (Reference value)
Approx. 0.45 kohms at 25 °C (77 °F)