suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

HVAC - Air Conditioning System|Page 4812 > < Diagram Information and Instructions|Page 4809
Page 1
background image

Blower Motor: Testing and Inspection
HVAC - Air Conditioning System

Blower Motor Controller Inspection

Reference: Blower Motor Controller Removal and Installation:Automatic Type

1. Check internal circuit of controller for resistance as follows.

a. Measure resistance between "1" terminal and "2" terminal of blower motor controller.

Blower motor controller resistance
"1" - "2": approximately 10 kohms

If resistance does not meet above specification, replace blower motor controller.

b. Using ohmmeter, connect its positive terminal to "3" terminal of blower motor controller and negative terminal to "1" terminal of blower motor

controller and check that there is no continuity.

2. Check controller for operation as follows.

HVAC - Air Conditioning System|Page 4812 > < Diagram Information and Instructions|Page 4809