SX4 4WD L4-2.0L (2008)
EVAP canister purge valve specification
Valve OFF [A]: When vacuum (-53 kPa (-7.69 psi) to -67 kPa (-9.72 psi)) is applied to hose (1), vacuum is maintained.
Valve ON [B]: When vacuum is applied to hose (1), air goes into hose.
Special Tool
(A) : 09917 47011