toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 2844 > < Diagram Information and Instructions|Page 2842
Page 1
background image

Air Flow Meter/Sensor: Testing and Inspection

INSPECTION 

Ohmmeter Connection

Reference

1. INSPECT MAF METER RESISTANCE

Using an ohmmeter, measure the resistance between terminals THA and E2.
If the resistance is not as specified, replace the MAF meter.

2. INSPECT MAF METER OPERATION

(a) Connect the MAF meter connector
(b) Turn the ignition switch ON.

(c) Using a voltmeter, connect the positive (+) tester probe to terminal VG and negative (-) tester probe to terminal E2G.
(d) Blow air into the MAF meter and check that the voltage fluctuates.

If operation is not as specified, replace the MAF meter.

(e) Turn the ignition switch OFF.
(f)  Disconnect the MAF meter connector.

Diagram Information and Instructions|Page 2844 > < Diagram Information and Instructions|Page 2842