Radiator Cooling Fan Motor: Initial Inspection and Diagnostic Overview

ON-VEHICLE INSPECTION

1. CHECK COOLING FAN OPERATION WITH LOW TEMPERATURE (Below 88°C (190°F))

a. Turn the ignition switch ON.
b. Check that the cooling fan stops.

If not, check the cooling fan relay and ECT switch, and check for a separated connector or severed wire between the cooling fan relay and
ECT switch.

c. Disconnect the No.1 ECT switch connector.

d. Check that the cooling fan rotates.

If not, check the fuses, engine main relay, cooling fan relay, cooling fan, and check for a short circuit between the cooling fan relay and ECT
switch.

e. Reconnect the No.1 ECT switch connector.

2. CHECK COOLING FAN OPERATION WITH HIGH TEMPERATURE (Above 98°C (208°F))

a. Start the engine, and raise coolant temperature to above 98°C (208°F).
b. Check that the cooling fan rotates. If not, replace the No.1 ECT switch.

3. INSPECT NO.1 COOLING FAN

a. Disconnect the cooling fan connector.
b. Connect battery and ammeter to the cooling fan connector.
c. Check that the cooling fan rotates smoothly, and check the reading on the ammeter.

Standard amperage: 8.3 - 11.3 A at 20°C (68°F)