Camry Solara SLEV6 V6-3.0L (1MZ-FE) (2000)
d. Reconnect the cooling fan connector.
4. INSPECT NO.2 COOLING FAN
a. Disconnect the cooling fan connector.
b. Connect battery and ammeter to the cooling fan connector.
c. Check that the cooling fan rotates smoothly, and check the reading on the ammeter.
Standard amperage: 8.3 - 11.3 A at 20°C (68°F)
d. Reconnect the cooling fan connector.
1. INSPECT CONDENSER FAN OPERATION
Inspect the fan operation, as shown in the chart.
Test conditions:
-
Ignition switch ON
-
Blower speed control switch position "HI"
-
A/C switch ON
If operation is not as specified, proceed next inspection.
2. INSPECT CONDENSER FAN MOTOR OPERATION
a. Disconnect the fan connector.
b. Connect the battery and ammeter to the connector, as shown in the illustration.
c. Check that the fan rotates smoothly, and then check that the reading on the ammeter.
Specified amperage: 10.1 ± 1.8 A at 20 °C (68 °F)
If operation is not as specified, replace the fan motor.
If operation is as specified, check the pressure switch, cooling fan relays and engine coolant temp. switch.