Testing of HVAC Condenser Fan Motor Relay No 2 for Corolla Wagon, 1993
Condenser Fan Motor Relay: Testing and Inspection
Fan Relay Number 3
Testing Condenser Fan Number 3
INSPECT RELAY OPERATION
With No Power Applied
Continuity should exist between terminals 1 and 2. If not as specified, replace the relay.
With Power Applied
Apply power to terminals 1 and 2. Continuity should exist between terminals 3 and 4. If not as specified, replace the relay.