Echo L4-1.5L (1NZ-FE) (2000)
Replacement Procedure
1.
Detach the damper control cable from Procedure Lever 1.
2.
Remove Screws 1 and 2, Lever 1 and Lever 2.
3.
Remove the damper plate.
4.
Remove Lever 3. Use a flat tool placed under the Lever and apply pressure in the outward direction.
5.
Replace Lever 3 with the new part.
CAUTION:
When installing the damper plate to the lever arms it is extremely important to have the lever arms in the correct position.