Hose/Line HVAC: Specifications

REFRIGERANT LINES TORQUE

NOTE:  Connections should not be torque tighter than the specified torque.

Compressor x Discharge hose ..................................................................................................................................................  10 N.m (100 kgf.cm, 7 ft.lbf)
Compressor x Suction hose ......................................................................................................................................................  10 N.m (100 kgf.cm, 7 ft.lbf)
Condenser x Discharge hose ....................................................................................................................................................  10 N.m (100 kgf.cm, 7 ft.lbf)
Condenser x Liquid tube ..........................................................................................................................................................  10 N.m (100 kgf.cm. 7 ft.lbf)
Pressure switch x Liquid tube ..................................................................................................................................................  10 N.m (100 kgf.cm, 7 ft.lbf)
A/C unit x Liquid tube .............................................................................................................................................................  10 N.m (100 kgf.cm. 7 ft.lbf)
Expansion valve x Evaporator ................................................................................................................................................  5.4 N.m (55 kgf.cm. 48 in.lbf)
A/C unit x Suction tube ............................................................................................................................................................  10 N.m (100 kgf.cm, 7 ft.lbf)
Liquid line (union nut) ...........................................................................................................................................................  14 N.m (140 kgf.cm, 10 ft.lbf)
Suction line (bolt) ....................................................................................................................................................................  10 N.m (100 kgf.cm, 7 ft.lbf)