toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Sight Glass, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 5505
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

PRESSURE SWITCH REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

INSTALLATION HINT:  Evacuate air from refrigeration system.

See: Service and Repair/Discharging & Evacuating System

Charge system with refrigerant and inspect for leakage of refrigerant.

See: Service and Repair/Charging the System

Specified amount:

600 ± 50 g (21.17 ± 1.76 oz.)

2. REMOVE PRESSURE SWITCH FROM LIQUID TUBE

Disconnect the connector and remove the pressure switch.

Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)

INSTALLATION HINT:  Lubricate a new O-ring with compressor oil and install the switch.

HINT:  Lock the switch mount on the tube with an open end wrench. being careful not to deform the tube, and remove the switch.

PRESSURE SWITCH INSTALLATION

Installation is in the reverse order of removal.

Sight Glass, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 5505