Evaporator Case: Testing and Inspection
On-Vehicle Inspection

COOLING UNIT

ON-VEHICLE INSPECTION

1. INSPECT FOR LEAKAGE OF REFRIGERANT

a. Remove the glove compartment door.
b. Remove the lower No.2 finish panel.
c. Remove the lower center cover.
d. Remove the lower LH finish panel.
e. Remove the lower cover.

f.

Remove the blower resistor.
1. Disconnect the connector.
2. Remove the 2 screws and blower resistor.

g. Using a gas leak detector, check for leakage.

If there is leakage, check the tightening torque at the joints or check the evaporator.

h. Install the blower resistor with the 2 screws.
i.

Install the lower cover.

j.

Install the lower LH finish panel.

k. Install the lower center cover.
l.

Install the lower No.2 finish panel.

m. Install the glove compartment door.

2. INSPECT EXPANSION VALVE

a. Check quantity of gas during refrigeration cycle.
b. Set on manifold gauge set.
c. Run engine.

1. Run the engine at 1,500 rpm for at least 5 minutes.
2. Then check that the high pressure reading is 1.37 - 1.57 Mpa (14 - 16 kgm/sq.cm, 199 - 288 psi).

d. Check expansion valve.

If the expansion valve is faulty, the low pressure reading will drop to 0 kPa (0 kgf/sq.cm, 0 psi).

HINT:  When the lower pressure drop to 0 kPa (0 kgf/sq.cm, 0 psi), feel the receiver's IN and OUT sides for no temperature difference.