vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0: DATA LIST - Test Step 12 - OIL LEVEL STATUS > < F0: DATA LIST - Test Step 10 - COOLANT LEVEL STATUS

F0:DATA LIST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Values

Trouble Codes

Terminal

 

11

OIL LEVEL SWITCH

 

Ignition ON

CLOSED        0V

-

X 20 3/13

 

Notes for Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Check engine oil level:

OK

·   Top up engine oil to maximum mark on oil dipstick

 

·   Disconnect plug from engine oil residue switch S 95

·   Ignition ON:

 OPEN  12V

·   Lead from X 20/Ter. 3 to engine oil residue switch S 95 has short circuit to ground

·   MID defective

 

·   Short-circuit contacts of switch plug:

CLOSED 0V

·   Lead from X 20/Ter. 3 to engine oil residue switch S 95 is interrupted

·   Lead from S 95 to ground is interrupted

·   MID defective

 

·   If nominal values are attained

 

 

·   Switch S 95 defective

 

 

 

F0: DATA LIST - Test Step 12 - OIL LEVEL STATUS > < F0: DATA LIST - Test Step 10 - COOLANT LEVEL STATUS