Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A1_A60 Controls - Heating/Air Conditioning (Wiring Harness Connector XC40 )
- Ignition ON
- Measure voltage between the following terminals:
A1_A60 Controls - Heating/Air Conditioning Wiring harness connector (wiring harness side) terminal 6 (XC40) & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Circuit Interruption of Ground Circuit
|
- Measure voltage between the following terminals:
A1_A60 Controls - Heating/Air Conditioning Wiring harness connector (wiring harness side) terminal 6 (XC40) & A1_A60 Controls - Heating/Air Conditioning Wiring harness connector (wiring harness side) terminal 23 (XC40)
|
greater than 11 V
|
|
|
T003
|
Check: Short to Ground of Signal Circuit
|
- Select the following Functional System on the diagnostic tester:
Instrument
- Diagnostic Tester Data List Parameter
Defrost Switch
|
Inactive
|
|
|
T004
|
Check: Short to Voltage/Interruption of Signal Circuit
|
- Connect fused jumper wire to:
A1_A60 Controls - Heating/Air Conditioning Wiring harness connector (wiring harness side) terminal 12 (XC40) & Ground
- Diagnostic Tester Data List Parameter
Defrost Switch
|
Active
|
|
|
T005
|
Check: Short to Voltage/Interruption of Signal Circuit
|
- Check the following component for proper operation:
Fuse of the fused jumper wire
|
Test okay?
|
|
T006
|
Check: Vehicle Configuration
|
Is the following information correct for the actual vehicle?
Vehicle with REC (Rear Electronic Module)
|
|
|