vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-041 Fuse FB5 Circuit > < C-039 Fuse FB3 Circuit

C-040 - Fuse FB4 Circuit

Test

Work Order Description

Nominal Value

T001

Check: Short to Ground of Voltage Supply Circuit

  • Ignition OFF
  • All consumers turned off
  • Remove electrical component from socket:
    FB4 Fuse
  • Disconnect wiring harness connector from:
    A12 Add-On Heater
  • Connect fused jumper wire to:
    FB4 Fuse
    Output contact
    &
    Battery voltage
  • Check the following component for proper operation:
    Fuse of the fused jumper wire

Test okay?

Yes: No:


Result

Cause Of Fault

E001 Result: System Overload
  • Defective component:
    A12 Add-On Heater
    or
  • A temporary current overload in the system behind fuse FB4 has occurred

Note:

If the defective component is a control unit, the cause for the fault may be located in a circuit behind that component.

In case of a temporary current overload, the cause for the blow of the fuse may be located in a circuit behind the control unit/component.

These circuits should be checked additionally for short to ground.

E002 Result: Short to Ground
  • Short circuit to ground between:
    FB4 Fuse
    Output contact
    &
    A12 Add-On Heater
    Wiring harness connector (wiring harness side) terminal 1P





C-041 Fuse FB5 Circuit > < C-039 Fuse FB3 Circuit