vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-058 Fuse FE16 Circuit > < C-056 Fuse FE14 Circuit

C-057 - Fuse FE15 Circuit

Test

Work Order Description

Nominal Value

T001

Check: Short to Ground of Voltage Supply Circuit

  • Ignition OFF
  • Reconnect all disconnected components
  • All consumers turned off
  • Remove electrical component from socket:
    K5_X125 Relay - Wiper, Windscreen, Low/High
  • Connect unfused jumper wire to:
    K5_X125 Relay - Wiper, Windscreen, Low/High
    Socket Terminal 87A
    &
    Battery voltage
  • Insert new component:
    FE15 Fuse
  • Check the following component for proper operation:
    FE15 Fuse

Test okay?

Yes: No:
T002

Check: Short to Ground of Voltage Supply Circuit

  • Do not remove unfused jumper wire
  • Disconnect wiring harness connector from:
    M17 Motor - Wiper, Windscreen
  • Insert new fuse FE15 and then check the fuse for proper operation.

Test okay?

Yes: No:


Result

Cause Of Fault

E001 Result: System Overload
  • A temporary current overload in the system behind fuse FE15 has occurred
E002 Result: Defective Component
  • If the nominal value is reached during one of the measurements, the component/control unit that has been disconnected immediately before that measurement is defective.
E003 Result: Short to Ground
  • Short circuit to ground between:
    X125 Underhood Electronic Module
    Socket Terminal 57 (XE2)
    &
    M17 Motor - Wiper, Windscreen
    Wiring harness connector (wiring harness side) terminal 2

or

  • Defective component:
    X125 Underhood Electronic Module

Note:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.






C-058 Fuse FE16 Circuit > < C-056 Fuse FE14 Circuit