The following test steps must be performed in the given order. If a fault is found in one test step, the subsequent test steps can be skipped.
Programming
After replacing 1 or more injectors, the following programming function has to be performed:
After replacing the following component the programming function for the replacement of the corresponding component has to be performed by using the diagnostic tester:
Air Mass Meter
-
B176 Sensor - Rail Fuel Pressure
-
- After programming successfully, check if the system malfunction is still present.
After successful test/fault repair proceed to the next test step
|