DTC
|
Diagnostic Trouble Code Storage Condition
|
P0001
|
Fuel Metering Solenoid Valve Circuit Open
|
- Interruption in circuit to control unit terminal 19, 49 (XC11)
- Above conditions must be fulfilled for at least 0.22 s .
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0001
|
Fuel Metering Solenoid Valve Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.28 s .
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0002
|
Fuel Metering Solenoid Valve Circuit Range/Performance
|
- The control unit recognises a difference between desired and actual value.
Oil pressure common rail too high or Oil pressure common rail too low
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0003
|
Fuel Metering Solenoid Valve Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 49 (XC11)
- Above condition must be fulfilled for at least 0.28 s .
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0004
|
Fuel Metering Solenoid Valve Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 49 (XC11)
- Above condition must be fulfilled for at least 0.22 s .
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0016
|
Crankshaft/Camshaft Correlation
|
- Engine running
- The control unit cannot synchronise the camshaft signal.
Effect:
- The telltale is switched on.
|
Concerned Terminals: ECM: 7, 12, 27 (XC11)
|
Remedy:
|
P0070
|
Ambient Air Temperature Sensor Malfunction
|
- Invalid data exchange between DIS and ECM
|
Concerned Terminals: -
|
Remedy:
|
P0087
|
Rail Pressure Low Pressure
|
- Difference between actual and desired common rail pressure is greater than 20.0 MPa
- Above condition must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0088
|
Rail Pressure High Pressure
|
- Common rail pressure is greater than 175.0 MPa
Effect:
|
Concerned Terminals: ECM: 19, 49 (XC11)
|
Remedy:
|
P0100
|
Mass Or Volume Air Flow Circuit Malfunction
|
- Short to voltage/ground or interruption in circuit to control unit terminal 42 (XC11)
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0100
|
Mass Or Volume Air Flow Circuit High Input
|
- Short to voltage in circuit to control unit terminal 42 (XC11)
- Above condition must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0100
|
Mass Or Volume Air Flow Circuit Low Input
|
- The voltage at the control unit input (terminal 42 (XC11) ) is too low.
(Short circuit to ground)
- Above condition must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0100
|
Mass or Volume Air Flow Sensor Circuit Range/Performance
|
- The sensor signal at control unit terminal 42 (XC11) is noisy.
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0100
|
Intake Air Temperature Sensor Circuit Low Input
|
- The control unit recognises a malfunction via an internal evaluation logic at the following component:
Air Mass Meter
- Above condition must be fulfilled for at least 2 s .
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0100
|
Intake Air Temperature Sensor Circuit High Input
|
- The control unit recognises a malfunction via an internal evaluation logic at the following component:
Air Mass Meter
- Above condition must be fulfilled for at least 2 s .
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0100
|
Intake Air Temperature Sensor Circuit Malfunction
|
- Short to voltage/ground or interruption in circuit to control unit terminal 44 (XC11)
- Above condition must be fulfilled for at least 0.58 s .
|
Concerned Terminals: ECM: 37, 42, 44 (XC11)
|
Remedy:
|
P0105
|
Boost Pressure Sensor Circuit Low Input
|
- The voltage at the control unit input (terminal 40 (XC11) ) is less than 0.2 V .
(Short circuit to ground)
Replacement Value:
- The control unit calculates with replacement value of 800 hPa ( 0.8 bar ).
|
Concerned Terminals: ECM: 13, 23, 40 (XC11)
|
Remedy:
|
P0105
|
Boost Pressure Sensor Circuit High Input
|
- The voltage at the control unit input (terminal 40 (XC11) ) is greater than 4.9 V .
(Short circuit to voltage or circuit interruption)
Replacement Value:
- The control unit calculates with replacement value of 800 hPa ( 0.8 bar ).
|
Concerned Terminals: ECM: 13, 23, 40 (XC11)
|
Remedy:
|
P0105
|
Barometric Pressure not plausible with Boost Pressure
|
- Engine speed is less than 950 rpm
- The difference between the boost pressure sensor and the barometric pressure sensor is greater than 10.2 kPa ( 0.102 bar )
- Above conditions must be fulfilled for at least 7 s .
|
Concerned Terminals: ECM: 13, 23, 40 (XC11)
|
Remedy:
|
P0115
|
Engine Coolant Temperature Circuit Low Input
|
- The voltage at the control unit input (terminal 41, 58 (XC11) ) is less than 0.35 V .
- Above condition must be fulfilled for at least 0.5 s .
|
Concerned Terminals: ECM: 41, 58 (XC11)
|
Remedy:
|
P0115
|
Engine Coolant Temperature Circuit High Input
|
- The voltage at the control unit input (terminal 41, 58 (XC11) ) is greater than 4.95 V .
- Above condition must be fulfilled for at least 2 s .
|
Concerned Terminals: ECM: 41, 58 (XC11)
|
Remedy:
|
P0115
|
Engine Coolant Temperature Sensor Circuit Range/Performance
|
- Engine coolant temperature increases too slow
The trouble code recognition is enabled, if the following conditions are fulfilled:
- Engine speed is greater than 1000 rpm
- The fuel quantity injected is greater than 5 mm^3
- Coolant temperature is greater than 38 °C (100 °F)
- Above conditions must be fulfilled for at least 8 min.
|
Concerned Terminals: ECM: 41, 58 (XC11)
|
Remedy:
|
P0190
|
Rail Pressure Sensor Low Voltage
|
- The voltage at the control unit input (terminal 43 (XC11) ) is less than 0.25 V .
- Above condition must be fulfilled for at least 0.14 s .
|
Concerned Terminals: ECM: 8, 28, 43 (XC11)
|
Remedy:
|
P0190
|
Rail Pressure Sensor High Voltage
|
- The voltage at the control unit input (terminal 43 (XC11) ) is greater than 4.76 V .
- Above condition must be fulfilled for at least 0.14 s .
|
Concerned Terminals: ECM: 8, 28, 43 (XC11)
|
Remedy:
|
P0201
|
Cylinder 1 Injector Circuit Open
|
- Circuit interruption to control unit terminal 16, 47 (XC11)
|
Concerned Terminals: ECM: 16, 47 (XC11)
|
Remedy:
|
P0202
|
Cylinder 2 Injector Circuit Open
|
- Circuit interruption to control unit terminal 2, 31 (XC11)
|
Concerned Terminals: ECM: 2, 31 (XC11)
|
Remedy:
|
P0203
|
Cylinder 3 Injector Circuit Open
|
- Circuit interruption to control unit terminal 1, 46 (XC11)
|
Concerned Terminals: ECM: 1, 46 (XC11)
|
Remedy:
|
P0204
|
Cylinder 4 Injector Circuit Open
|
- Circuit interruption to control unit terminal 17, 33 (XC11)
|
Concerned Terminals: ECM: 17, 33 (XC11)
|
Remedy:
|
P0219
|
Engine Overspeed Condition
|
- Engine speed was greater than 6000 rpm
Effect:
- Engine is stopped.
- Engine telltale is switched on
|
Concerned Terminals: ECM: 7, 12, 27 (XC11)
|
Remedy:
|
P0234
|
Boost Pressure Control Circuit Negative Deviation
|
- The boost pressure is too high
Effect:
- Exhaust gas recirculation valve is switched off
- Boost pressure control is not longer possible.
|
Concerned Terminals: ECM: 13, 23, 40 (XC11)
|
Remedy:
|
P0234
|
Boost Pressure Control Circuit Positive Deviation
|
- The boost pressure is too low
Effect:
- Exhaust gas recirculation valve is switched off
- Boost pressure control is not longer possible.
|
Concerned Terminals: ECM: 13, 23, 40 (XC11)
|
Remedy:
|
P0243
|
Boost Pressure Valve High Voltage
|
- Short to voltage in circuit to control unit terminal 15 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 15 (XC11)
|
Remedy:
|
P0243
|
Boost Pressure Valve Low Voltage
|
- Short to ground in circuit to control unit terminal 15 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 15 (XC11)
|
Remedy:
|
P0243
|
Boost Pressure Valve Circuit Open
|
- Short to ground or interruption in circuit to control unit terminal 15 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 15 (XC11)
|
Remedy:
|
P0243
|
Boost Pressure Valve Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 15 (XC11)
|
Remedy:
|
P0262
|
Cylinder 1 Injector Circuit High
|
- Short circuit in wiring harness between terminal 16 (XC11) and terminal 47 (XC11)
|
Concerned Terminals: ECM: 16, 47 (XC11)
|
Remedy:
|
P0265
|
Cylinder 2 Injector Circuit High
|
- Short circuit in wiring harness between terminal 2 (XC11) and terminal 31 (XC11)
|
Concerned Terminals: ECM: 2, 31 (XC11)
|
Remedy:
|
P0268
|
Cylinder 3 Injector Circuit High
|
- Short circuit in wiring harness between terminal 1 (XC11) and terminal 46 (XC11)
|
Concerned Terminals: ECM: 1, 46 (XC11)
|
Remedy:
|
P0271
|
Cylinder 4 Injector Circuit High
|
- Short circuit in wiring harness between terminal 17 (XC11) and terminal 33 (XC11)
|
Concerned Terminals: ECM: 17, 33 (XC11)
|
Remedy:
|
P0335
|
Crankshaft Position Sensor "A" Circuit Range/Performance
|
- Crankshaft Position variation is not within an acceptable range, or can not be learned
|
Concerned Terminals: ECM: 7, 12, 27 (XC11)
|
Remedy:
|
P0335
|
Crankshaft Position Sensor "A" Circuit Open
|
Effect:
Engine is stopped.
|
Concerned Terminals: ECM: 7, 12, 27 (XC11)
|
Remedy:
|
P0340
|
Camshaft Position Sensor Circuit Range/Performance
|
- Engine speed is greater than 60 rpm
- The control unit recognises no or an implausible camshaft signal.
- Above conditions must be fulfilled for at least 1 s .
|
Concerned Terminals: ECM: 20, 50 (XC11)
|
Remedy:
|
P0340
|
Camshaft Position Sensor Circuit Open
|
- Camshaft signal not recognised
Note:
A sudden loss of the crankshaft signal during operation (without intermittent) could only be recognised at the following engine start.
|
Concerned Terminals: ECM: 20, 50 (XC11)
|
Remedy:
|
P0380
|
Glow Device Circuit High Voltage
|
- Final stage diagnosis in control unit
(Short circuit to voltage)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 52, 93 (XC12)
|
Remedy:
|
P0380
|
Glow Device Circuit Low Voltage
|
- Final stage diagnosis in control unit
(Short circuit to ground)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 52, 93 (XC12)
|
Remedy:
|
P0380
|
Glow Device Circuit Open Circuit
|
- Final stage diagnosis in control unit
(Circuit interruption)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 52, 93 (XC12)
|
Remedy:
|
P0380
|
Glow Device General Error
|
- Failure in glow device circuit
- Above conditions must be fulfilled for at least 2.5 s .
|
Concerned Terminals: ECM: 52, 93 (XC12)
|
Remedy:
|
P0380
|
Glow Device Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 52, 93 (XC12)
|
Remedy:
|
P0400
|
Exhaust Gas Recirculation Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 34 (XC11)
- Above condition must be fulfilled for at least 3 s .
|
Concerned Terminals: ECM: 9, 34, 51, 57 (XC11)
|
Remedy:
|
P0400
|
Exhaust Gas Recirculation Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 34 (XC11)
- Above condition must be fulfilled for at least 3 s .
|
Concerned Terminals: ECM: 9, 34, 51, 57 (XC11)
|
Remedy:
|
P0400
|
Exhaust Gas Recirculation Circuit Open
|
- Interruption in circuit to control unit terminal 34 (XC11)
- Above conditions must be fulfilled for at least 3 s .
|
Concerned Terminals: ECM: 9, 34, 51, 57 (XC11)
|
Remedy:
|
P0400
|
Exhaust Gas Recirculation Flow Insufficient Detected
|
- The actual exhaust-gas recirculation flow value is less than the nominal exhaust-gas recirculation flow value
Effect:
- Exhaust gas recirculation valve is switched off
- Boost pressure control is not longer possible.
- The fuel injection quantity is reduced.
|
Concerned Terminals: ECM: 9, 34, 51, 57 (XC11)
|
Remedy:
|
P0400
|
Exhaust Gas Recirculation Flow Excessive Detected
|
- Actual exhaust gas recirculation quantity is too great
Effect:
- Exhaust gas recirculation valve is switched off
- Boost pressure control is not longer possible.
|
Concerned Terminals: ECM: 9, 34, 51, 57 (XC11)
|
Remedy:
|
P0400
|
Exhaust Gas Recirculation Valve Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 3 s .
|
Concerned Terminals: ECM: 9, 34, 51, 57 (XC11)
|
Remedy:
|
P0500
|
Vehicle Speed Signal not plausible with Engine Speed and Injection Mass
|
- The control unit receives the following signal not or wrong:
Vehicle Speed Input Signal or
- The fuel consumption is too high for the corresponding power output.
|
Concerned Terminals: -
|
Remedy:
|
P0500
|
Vehicle Speed Signal Range/Performance
|
- The control unit receives the following signal not or wrong:
Vehicle Speed Input Signal
|
Concerned Terminals: -
|
Remedy:
|
P0530
|
A/C Pressure Sensor Circuit Low Input
|
- The voltage at control unit terminal 13 (XC12) is less than 0.1 V
The trouble code recognition is enabled, if the following conditions are fulfilled:
- Engine idling
- Intake air temperature is greater than 5 °C (41 °F)
- Above conditions must be fulfilled for at least 1 s .
|
Concerned Terminals: ECM: 12, 13, 22 (XC12)
|
Remedy:
|
P0530
|
A/C Pressure Sensor Circuit High Input
|
- The voltage at control unit terminal 13 (XC12) is greater than 4.9 V
The trouble code recognition is enabled, if the following conditions are fulfilled:
- Engine idling
- Intake air temperature is greater than 5 °C (41 °F)
- Above conditions must be fulfilled for at least 1 s .
|
Concerned Terminals: ECM: 12, 13, 22 (XC12)
|
Remedy:
|
P0620
|
Generator Lamp "L" Control Circuit Malfunction
|
- Short to voltage in circuit to control unit terminal 19 (XC12)
- Above condition must be fulfilled for at least 5 s .
|
Concerned Terminals: 19, 75 (XC12)
|
Remedy:
|
P0621
|
Generator Lamp "L" Control Circuit Malfunction
|
- Incorrect voltage level at control unit terminal 19 (XC12)
(Short circuit to ground/voltage or circuit interruption)
|
Concerned Terminals: 19, 75 (XC12)
|
Remedy:
|
P0622
|
Generator Field "F" Control Circuit Malfunction
|
- Short to voltage/ground or interruption in circuit to control unit terminal 75 (XC12)
The trouble code recognition is enabled, if the following conditions are fulfilled:
- Ignition ON
- Engine OFF
- Above conditions must be fulfilled for at least 2 s .
|
Concerned Terminals: 19, 75 (XC12)
|
Remedy:
|
P0638
|
Electronic Throttle Control High Voltage
|
- Short to voltage in circuit to control unit terminal 59 (XC11)
- Above conditions must be fulfilled for at least 3 s .
|
Concerned Terminals: ECM: 52, 59 (XC11)
|
Remedy:
|
P0638
|
Electronic Throttle Control Low Voltage
|
- Short to ground or interruption in circuit to control unit terminal 59 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 52, 59 (XC11)
|
Remedy:
|
P0638
|
Electronic Throttle Control Circuit open
|
- Short to ground or interruption in circuit to control unit terminal 59 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 52, 59 (XC11)
|
Remedy:
|
P0638
|
Electronic Throttle Control Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 52, 59 (XC11)
|
Remedy:
|
P0641
|
5V Reference Circuit 1 Low Voltage
|
- The internal control unit reference voltage is less than 4.65 V .
|
Concerned Terminals: ECM: 45 (XC12)
|
Remedy:
|
P0641
|
5V Reference Circuit 1 High Voltage
|
- The internal control unit reference voltage is greater than 5.35 V .
|
Concerned Terminals: ECM: 45 (XC12)
|
Remedy:
|
P0651
|
5V Reference Circuit 2 Low Voltage
|
- The internal control unit reference voltage is less than 4.65 V .
|
Concerned Terminals: ECM: 13, 28 (XC11), 46 (XC12)
|
Remedy:
|
P0651
|
5V Reference Circuit 2 High Voltage
|
- The internal control unit reference voltage is greater than 5.35 V .
|
Concerned Terminals: ECM: 13, 28 (XC11), 46 (XC12)
|
Remedy:
|
P0697
|
5V Reference Circuit 3 Low Voltage
|
- The internal control unit reference voltage is less than 4.65 V .
|
Concerned Terminals: ECM: 9 (XC11), 22 (XC12)
|
Remedy:
|
P0697
|
5V Reference Circuit 3 High Voltage
|
- The internal control unit reference voltage is greater than 5.35 V .
|
Concerned Terminals: ECM: 9 (XC11), 22 (XC12)
|
Remedy:
|
P0703
|
Brake Switch Circuit Malfunction
|
- Engine speed is greater than 1350 rpm
- The trouble code is stored, if brake pedal and accelerator pedal are actuated at the same time.
Effect:
- Engine speed is controlled to a fixed value of 850 rpm
Note:
The fault detection is only possible if the brake-light switch is operational. The trouble code will be set, if the pedal position sensor has a malfunction or the pedal position is implausible.
|
Concerned Terminals: ECM: 17, 80 (XC12)
|
Remedy:
|
P0704
|
Clutch Switch Input Circuit Malfunction
|
- Vehicle accelerated from stop (from 1 km/h (1 mph) up to approximately 35 km/h (22 mph))
- No signal change of the clutch switch signal recognised
|
Concerned Terminals: ECM: 79 (XC12)
|
Remedy:
|
P1105
|
Barometric Pressure Sensor Circuit Low Input
|
- The control unit recognises the malfunction of the internal barometer sensor via an internal evaluation logic.
(Short circuit to ground)
Replacement Value:
- The control unit calculates with replacement values depending on the boost pressure.
|
Concerned Terminals: -
|
Remedy:
|
P1105
|
Barometric Pressure Sensor Circuit High Input
|
- The control unit recognises the malfunction of the internal barometer sensor via an internal evaluation logic.
(Short circuit to voltage)
Replacement Value:
- The control unit calculates with replacement values depending on the boost pressure.
|
Concerned Terminals: -
|
Remedy:
|
P1110
|
Swirl Actuator High Voltage
|
- Short to voltage in circuit to control unit terminal 45 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 45 (XC11)
|
Remedy:
|
P1110
|
Swirl Actuator Low Voltage
|
- Short to ground in circuit to control unit terminal 45 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 45 (XC11)
|
Remedy:
|
P1110
|
Swirl Actuator Circuit Open
|
- Short to ground or interruption in circuit to control unit terminal 45 (XC11)
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 45 (XC11)
|
Remedy:
|
P1110
|
Swirl Actuator Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.48 s .
|
Concerned Terminals: ECM: 45 (XC11)
|
Remedy:
|
P1120
|
Accelerator Pedal Position Sensor 1 High Input
|
- The voltage at the control unit input (terminal 9 (XC12) ) is greater than 4.7 V .
(Short circuit to voltage)
Effect:
- Accelerator pedal out of function
|
Concerned Terminals: ECM: 8, 9, 30, 31, 45, 46 (XC12)
|
Remedy:
|
P1120
|
Accelerator Pedal Position Sensor 1 Range/Performance
|
- Short to ground or interruption in circuit to control unit terminal 9 (XC12)
The trouble code recognition is enabled, if the following conditions are fulfilled:
- The voltage at control unit terminal 9 (XC12) is less than 0.15 V
& The voltage at control unit terminal 31 (XC12) is less than 0.15 V
|
Concerned Terminals: ECM: 8, 9, 30, 31, 45, 46 (XC12)
|
Remedy:
|
P1120
|
Accelerator Pedal Position Sensor 1 and 2 Signal Incorrect Ratio
|
- The control unit recognises a general plausibility error for the pedal position sensor.
|
Concerned Terminals: ECM: 8, 9, 30, 31, 45, 46 (XC12)
|
Remedy:
|
P1122
|
Accelerator Pedal Position Sensor 2 High Input
|
- The voltage at control unit terminal 31 (XC12) is greater than 2.5 V
(Short circuit to voltage)
|
Concerned Terminals: ECM: 8, 9, 30, 31, 45, 46 (XC12)
|
Remedy:
|
P1122
|
Accelerator Pedal Position Sensor 2 Range/Performance
|
- Short to ground or interruption in circuit to control unit terminal 31 (XC12)
The trouble code recognition is enabled, if the following conditions are fulfilled:
- The voltage at control unit terminal 31 (XC12) is less than 0.15 V
& The voltage at control unit terminal 9 (XC12) is less than 0.15 V
|
Concerned Terminals: ECM: 8, 9, 30, 31, 45, 46 (XC12)
|
Remedy:
|
P1122
|
Accelerator Pedal Position Sensor 1 and 2 Signal Incorrect Ratio
|
- The control unit recognises a general plausibility error for the pedal position sensor.
|
Concerned Terminals: ECM: 8, 9, 30, 31, 45, 46 (XC12)
|
Remedy:
|
P1125
|
Throttle Actuator Feedback Signal Range/Performance
|
- Signal lead indicates an implausible value.
- Above condition must be fulfilled for at least 0.3 - 4 s .
|
Concerned Terminals: ECM: 52 (XC11)
|
Remedy:
|
P1180
|
Fuel Filter Heater High Voltage
|
- Short to voltage in circuit to control unit terminal 68
- Above condition must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 68 (XC12)
|
Remedy:
|
P1180
|
Fuel Filter Heater Low Voltage
|
- Short to ground in circuit to control unit terminal 68
- Above condition must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 68 (XC12)
|
Remedy:
|
P1180
|
Fuel Filter Heater Circuit Open
|
- Interruption in circuit to control unit terminal 68
- Above conditions must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 68 (XC12)
|
Remedy:
|
P1180
|
Fuel Filter Heater Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.3 s .
|
Concerned Terminals: ECM: 68 (XC12)
|
Remedy:
|
P1400
|
Exhaust Gas Recirculation Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 57 (XC11)
- Above condition must be fulfilled for at least 4 s .
|
Concerned Terminals: ECM: 9, 51, 57 (XC11)
|
Remedy:
|
P1400
|
Exhaust Gas Recirculation Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 57 (XC11)
- Above condition must be fulfilled for at least 4 s .
|
Concerned Terminals: ECM: 9, 51, 57 (XC11)
|
Remedy:
|
P1400
|
Exhaust Gas Recirculation Circuit Range/Performance
|
- The control unit recognises an implausible position of the exhaust gas recirculation valve.
- Above conditions must be fulfilled for at least 10 s .
|
Concerned Terminals: ECM: 9, 51, 57 (XC11)
|
Remedy:
|
P1400
|
Exhaust Gas Recirculation Valve Stuck
|
- The control unit recognises an implausible position of the exhaust gas recirculation valve.
- Above conditions must be fulfilled for at least 5 s .
|
Concerned Terminals: ECM: 9, 51, 57 (XC11)
|
Remedy:
|
P1481
|
Fan Control 1 Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 90 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1481
|
Fan Control 1 Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 90 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1481
|
Fan Control 1 Circuit Open
|
- Interruption in circuit to control unit terminal 90 (XC12)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1481
|
Fan Control 1 Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1482
|
Fan Control 2 Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 69 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1482
|
Fan Control 2 Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 69 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1482
|
Fan Control 2 Circuit Open
|
- Interruption in circuit to control unit terminal 69 (XC12)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1482
|
Fan Control 2 Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1483
|
Fan Control 3 Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 94 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1483
|
Fan Control 3 Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 94 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1483
|
Fan Control 3 Circuit Open
|
- Interruption in circuit to control unit terminal 94 (XC12)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1483
|
Fan Control 3 Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: -
|
Remedy:
|
P1530
|
A/C Relay Voltage High
|
- Short to voltage in circuit to control unit terminal 29 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 29 (XC12)
|
Remedy:
|
P1530
|
A/C Relay Voltage Low
|
- Short to ground in circuit to control unit terminal 29 (XC12)
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 29 (XC12)
|
Remedy:
|
P1530
|
A/C Relay Circuit Open
|
- Interruption in circuit to control unit terminal 29 (XC12)
- Above conditions must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 29 (XC12)
|
Remedy:
|
P1530
|
A/C Relay Powerstage High Temperature
|
- The ascertained Control Unit temperature is out of range.
- Above condition must be fulfilled for at least 0.6 s .
|
Concerned Terminals: ECM: 29 (XC12)
|
Remedy:
|
P1560
|
System Voltage Malfunction
|
- The voltage measurement results an implausible value.
- Above condition must be fulfilled for at least 0.1 s .
|
Concerned Terminals: ECM: 1, 3, 5, 72 (XC12)
|
Remedy:
|
P1610
|
Immobiliser Function not Programmed
|
- The engine control unit is in reset state.
Effect:
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1610
|
Immobiliser Malfunction
|
- The engine control unit is in reset state.
|
Concerned Terminals: -
|
Remedy:
|
P1611
|
Wrong Security Code Entered
|
- Entered security code is not valid for the actual vehicle
Effect:
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1613
|
Immobiliser No Or Wrong Signal
|
- Communication error between the CIM and the engine control unit.
Effect:
- Engine operation is impossible.
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1614
|
Immobiliser Wrong Signal Received
|
- Communication error between the CIM and the engine control unit.
Effect:
- Engine operation is impossible.
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1614
|
Wrong Transponder Key
|
- Wrong transponder response received.
or
- The Environment Identification failed.
Effect:
- Engine operation is impossible.
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1615
|
ECM (Engine Control Module) Identification Failed
|
- The engine control unit identification failed.
- Vehicle-ID not received
Effect:
- Engine operation is impossible.
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1616
|
CIM (Steering Column Module) Wrong Environment Identifier
|
- The Environment Identification failed.
Effect:
- Engine operation is impossible.
- The Service Vehicle Soon Telltale is flashing.
|
Concerned Terminals: -
|
Remedy:
|
P1625
|
Main Relay opens too early
|
- Main relay shuts off too early.
Note:
If the main relay is shut off too early after the power down time of the control unit, the trouble codes will not be stored.
|
Concerned Terminals: ECM: 1, 3, 5, 72 (XC12)
|
Remedy:
|
P1625
|
Main Relay opens too late
|
- Main relay shuts off too late or not at all.
Note:
If the main relay is not switched off after the power down time of the control units, a time counter in the engine control unit is started. If the main relay does not switch off after an internally programmed time, the trouble code will be set.
|
Concerned Terminals: ECM: 1, 3, 5, 72 (XC12)
|
Remedy:
|
P1811
|
Torque Signal Malfunction (CAN)
|
- The control unit recognises a fault in the following system:
Anti-Lock Brake System
|
Concerned Terminals: -
|
Remedy:
|
P1815
|
Cruise Control Interface Malfunction
|
- Incorrect message or invalid data received from CIM
|
Concerned Terminals: -
|
Remedy:
|
P1895
|
Limp home - Limited Performance
|
- Mechanical engine problem
or
- Overheating of the system caused by overload
Effect:
- The fuel injection quantity is reduced.
Note:
This trouble code is set when an engine protection function is activated.
|
Concerned Terminals: -
|
Remedy:
|
P2147
|
Injector 1 or 4 Short Circuit
|
- The voltage condition measured by the control unit at the output driver to the injectors does not correspond to the nominal value
(Short circuit to ground or voltage)
|
Concerned Terminals: ECM: 1, 2, 16, 17, 31, 33, 46, 47 (XC11)
|
Remedy:
|
P2147
|
Injector 1 or 4 Malfunction
|
- The control unit recognises a difference between desired and actual value.
(Short circuit to ground)
|
Concerned Terminals: ECM: 1, 2, 16, 17, 31, 33, 46, 47 (XC11)
|
Remedy:
|
P2150
|
Injector 2 or 3 Short Circuit
|
- The voltage condition measured by the control unit at the output driver to the injectors does not correspond to the nominal value
(Short circuit to ground or voltage)
|
Concerned Terminals: ECM: 1, 2, 16, 17, 31, 33, 46, 47 (XC11)
|
Remedy:
|
P2150
|
Injector 2 or 3 Malfunction
|
- The control unit recognises a difference between desired and actual value.
(Short circuit to ground)
|
Concerned Terminals: ECM: 1, 2, 16, 17, 31, 33, 46, 47 (XC11)
|
Remedy:
|
P2279
|
Intake Air System Leak Detected
|
- The control unit recognises a mechanical malfunction of the following component via an internal evaluation logic:
Intake system
|
Concerned Terminals: -
|
Remedy:
|