vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-015 Swirl Level Control Circuit > < C-013 Boost Pressure Control Valve Circuit

C-014 - Throttle Valve Positioner Circuit

Test

Work Order Description

Nominal Value

T001

Check: Interruption of Voltage Supply Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    A111 Throttle Valve - Positioner
  • Ignition ON
  • Measure voltage between the following terminals:
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:
T002

Check: Circuit Interruption of Ground Circuit

  • Measure voltage between the following terminals:
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 2
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 1

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:
T003

Check: Short to Voltage of Signal Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    A84 Control Unit - Engine
    (Wiring Harness Connector XC11 )
  • Ignition ON
  • Measure voltage between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 59 (XC11)
    &
    Ground

less than 0.3 V

Voltage Measurement Current Value: V
Yes: No:
T004

Check: Short to Voltage of Signal Circuit

  • Measure voltage between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 52 (XC11)
    &
    Ground

less than 0.3 V

Voltage Measurement Current Value: V
Yes: No:
T005

Check: Short to Ground of Signal Circuit

  • Ignition OFF
  • Measure resistance between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 59 (XC11)
    &
    Ground

greater than 500 kOhm

Resistance Measurement Current Value: kOhm
Yes: No:
T006

Check: Short to Ground of Signal Circuit

  • Measure resistance between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 52 (XC11)
    &
    Ground

greater than 500 kOhm

Resistance Measurement Current Value: kOhm
Yes: No:
T007

Check: Interruption of Signal Circuit

  • Measure resistance between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 59 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 3

less than 5 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:
T008

Check: Interruption of Signal Circuit

  • Measure resistance between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 52 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 4

less than 5 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:


Result

Cause Of Fault

E001 Result: Defective Component
  • Defective component:
    A111 Throttle Valve - Positioner
    or
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

Note:

The replacement of the components must be done in the listed order.

E002 Result: Interruption
  • Circuit interruption between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 52 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 4
E003 Result: Interruption
  • Circuit interruption between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 59 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 3
E004 Result: Short to Ground
  • Short circuit to ground between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 52 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 4
E005 Result: Short to Ground
  • Short circuit to ground between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 59 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 3
E006 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 52 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 4
E007 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 59 (XC11)
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 3
E008 Result: Interruption
  • Circuit interruption between:
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 1
    &
    Ground
E009 Result: Interruption
  • Circuit interruption between:
    FE21 Fuse
    Output contact
    &
    A111 Throttle Valve - Positioner
    Wiring harness connector (wiring harness side) terminal 2





C-015 Swirl Level Control Circuit > < C-013 Boost Pressure Control Valve Circuit