Replace hot film mass air flow meter
Remove
2. |
Remove hot film mass air flow meter (1)
• |
Disconnect wiring harness plug (2)
|
• |
Detach 2x air intake hose
|
|
|
|
Install
Important: Before assembling
components of the intake system, these must be cleaned of any
possible contamination (grease, oil etc.)
|
3. |
Install hot-film mass air flow meter
Note: Arrow on hot film
air mass flow meter indicates the throughput direction
• |
Attach 2x air intake hose
|
• |
Fix wiring harness plug
|
|
|