Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B166 Sensor - Oxygen, Mixture Control, Heated
- Ignition ON
- Measure voltage between the following terminals:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 1 & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Circuit Interruption of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
M3 Motor - Radiator Fan and A84 Control Unit - Engine
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 49 (XC1) & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 2
|
less than 5 Ohm
|
|
|