Result
|
Cause Of Fault
|
E001
|
Result: Short to Ground/Interruption
|
- Short circuit to ground/interruption of circuit between:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 49 (XC99) & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 2
or
- Defective component:
A84 Control Unit - Engine
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E002
|
Result: Short to Ground
|
- Short circuit to ground between:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (component side) terminal 1 & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (component side) terminal 2
or
- Defective component:
B166 Sensor - Oxygen, Mixture Control, Heated
|
|
E003
|
Result: Interruption
|
- Circuit interruption between:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (component side) terminal 1 & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (component side) terminal 2
or
- Defective component:
B166 Sensor - Oxygen, Mixture Control, Heated
|
|
E004
|
Result: Short Circuit in Wiring Harness
|
- Short circuit in wiring harness between:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (component side) terminal 1 & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (component side) terminal 2
or
- Defective component:
B166 Sensor - Oxygen, Mixture Control, Heated
|
|
E005
|
Result: Short to Ground
|
- Short circuit to ground between:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 2 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 49 (XC99)
|
|
E006
|
Result: Short to Voltage
|
- Short circuit to voltage between:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 49 (XC99) & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 2
|
|
E007
|
Result: Interruption
|
- Circuit interruption between:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 29 (XE3) & B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 1
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|