Heated Oxygen Sensor Replacement - Sensor 1 (1.4L LDD)
Callout
|
Component Name
|
|
Warning:
In order to avoid being burned, do not service
the exhaust system while it is still hot. Service the system when
it is cool. |
Preliminary Procedure
Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection .
|
1
|
Heated Oxygen Sensor 1
Caution: Refer to
Fastener Caution .
Procedure
|
1. |
Disconnect the electrical connector and remove
wiring harness from retainer. |
|
2. |
When re-using the heated oxygen sensor, coat the
thread with assembly paste. |
Tighten
42 N·m (31 lb ft)
Special Tools
EN-48259 Installer/Remover
For equivalent regional tools, refer to
Special Tools
|
|
|
|