DTC P0560
Diagnostic Instructions
DTC Descriptor
DTC P0560: System Voltage - ECM |
Diagnostic Fault Information
Circuit
|
Short to Ground
|
Open/High Resistance
|
Short to Voltage
|
Signal Performance
|
B+
|
P0562
|
P0562
|
-
|
P0560
|
Ground
|
-
|
P0562
|
-
|
P0560
|
|
|
Circuit/System Description
The engine control module (ECM) monitors the system voltage to
ensure that the voltage stays within the proper range. Damage to
components, and incorrect data may occur when the voltage is out of
range.
Conditions for Running the DTC
The ignition is ON.
Conditions for Setting the DTC
The ECM detects a system voltage out of range for 2 seconds.
Action Taken When the DTC Sets
DTC P0560 is a C type DTC.
Conditions for Clearing the DTC
DTC P0560 is a C type DTC.
Diagnostic Aids
A low voltage DTC in multiple modules indicates a concern in the
charging system.
Reference Information
Schematic Reference
Connector End View Reference
Component Connector End Views
Description and Operation
Charging System Description and Operation
Electrical Information Reference
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
Engine running, accessories OFF, measure and record the battery
voltage at the battery terminals. The voltage should be between
12.6 and 15.0 V.
If not within the specified range, refer to
Charging System Test .
Circuit/System Testing
1. |
Ignition OFF, disconnect the
harness connectors at the K20 ECM. |
2. |
Ignition OFF and scan tool
disconnected, open and close the driver door, and wait 1 minute.
Test for less than 5 Ω between the ground circuit terminals
listed below and ground. |
|
• |
Terminal 2 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 4 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 6 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 1 X1 (LPL or
LPV) |
|
• |
Terminal 2 X1 (LPL or
LPV) |
|
• |
Terminal 3 X1 (LPL or
LPV) |
|
• |
Terminal 4 X1 (LPL or
LPV) |
|
• |
Terminal 32 X1 (LPL or
LPV) |
|
• |
Terminal 73 X2 (LDD, LUJ, LDE,
LLU) |
⇒ |
If greater than the specified range, test the
ground circuit for an open/high resistance. |
3. |
Ignition ON, verify that a
test lamp illuminates between the B+ circuit terminals listed below
and ground. |
|
• |
Terminal 1 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 3 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 5 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 46 X1 (LSF, LBS, or
LBX) |
|
• |
Terminal 9 X1 (LPL or
LPV) |
|
• |
Terminal 3 X1 (LDD, LDE,
LLU) |
|
• |
Terminal 12 X1 (LDD, LDE,
LLU) |
|
• |
Terminal 14 X1 (LDD, LDE,
LLU) |
⇒ |
If the test lamp does not illuminate, test the B+
circuit for a short to ground or an open/high resistance. |
4. |
If all circuits test normal,
replace the K20 ECM. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic
procedure.
Control Module References for ECM replacement, setup, and
programming
|