Catalytic Converter Heat Shield Replacement (LDE, LXV, 2H0, LUW
and LFH)
Removal Procedure
Warning: Refer to
Exhaust Service Warning .
Warning: Refer to
Protective Goggles and Glove
Warning .
3. |
Disconnect the heated oxygen
sensor wiring harness plug. |
5. |
Remove the wiring harness
bracket bolt (2) and the wiring harness bracket (1). |
6. |
Remove the 2 exhaust manifold
heat shield bolts (4). |
7. |
Remove the exhaust manifold
heat shield (3). |
Installation Procedure
1. |
Install the exhaust manifold
heat shield (3). |
2. |
Install the 2 exhaust manifold
heat shield bolts (4) and tighten to 8 N·m (71 lb
in) . |
3. |
Install the wiring harness
bracket (1) and the wiring harness bracket bolt (2) and tighten to
15 N·m (11 lb ft) . |
5. |
Connect the heated oxygen
sensor wiring harness plug. |
|