Turbocharger Air Inlet Adapter Installation
2. |
Install and position the
turbocharger air inlet adapter (1) |
3. |
Install and tighten the 2
turbocharger air inlet bolts (6) and 8 N·m (71 lb
in) . |
4. |
Install the turbocharger
wastegate regulator solenoid valve hose (5) to the turbocharger (4)
and install the clamp. |
5. |
Install the turbocharger
wastegate actuator hose (2) to the turbocharger wastegate actuator
(3) and the clamp. |
6. |
Install the charge air bypass
valve pipe (1) to the charge air bypass valve (2) and install the
clamp (3). |
|