Thermostatic Valve in Adapter, Replace

 

Remove retaining ring (arrow).

Press cover of thermostatic valve carefully out of valve borehole.

Beware of escaping oil.

Object Number: 2379436  Size: DEFAULT

 

 

Pull spring and thermostatic valve out of valve borehole.

Clean parts, check for damage and replace if necessary.

Installation is in the reverse order.

     Note:    Ensure correct installation of spring.

 

Check engine oil level and top up to "MAX" marking on dipstick if necessary.

Object Number: 2379429  Size: DEFAULT

 

 

 

 