F0: Data List - Test Step 06 COOLANT TEMP. > < F0: Data List - Test Step 04 TRANSM. CODING

 

 

 

 

 

 

Test

TECH 1

Notes

Nominal Values

Pin

Possible

Step

Display

 

 

 

Trouble

No.

 

 

 

 

Codes

 

 

 

 

 

 

 

 

 

 

 

 

05

INTAKE AIR TEMP.

Engine at idle speed,

10 to 50 °C/50 to 122 °F

44/26

69, 71

 

 

operating temperature

3.9 to 2.3 V

 

 

 

 

 

 

 

 

 

 

Trouble-shooting:                                      Nominal Value:                       Cause of Fault:

(If nominal value is not attained)

 

· Engine off, ignition ON

 

· Remove air flow meter                                            < - 35 °C/- 31 °F > 4.9 V                      · Short circuit of signal lead Ter. 5

plug                                                                                                                                               or Ter. 1 (with AFM without CO pot.)

to ground lead Ter. 4

· Ignition ON                                                                                                                               · Control unit defective

 

· Bridge Ter. 4 (-) with Ter. 5 or Ter. 1 > 180 °C/230 °F < 0.1 V                                        · Lead interruption from

(with AFM without CO pot.) at air                                                                                             - Control unit Ter. 44 to AFM Ter. 5 or Ter. 1

flow meter plug with adapter                                                                                                    - Control unit Ter. 26 to AFM Ter. 4

cables from KM-609                                                                                                                 · Poor plug connection (loose contact

caused by pushed-back pin on AFM)

· Control unit defective

 

If nominal values are attained          · Temperature sensor (AFM) defective

 

Intake air temperature sensor checking                 Note:       The terminal designation is located under the

values Ter. 5 or Ter. 1 (signal lead)/Ter.                                  the insulation of the wiring harness plug to the AFM.

4 (-): + 15 to + 30 °C/50 to 86 °F:

1450 to 3300 W

 

 


Related Literature Units
-Table 2 - Trouble Code Table: Trouble Code 69
-