07

AIR FLOW SENSOR

Engine at idle speed,

0.5 to 1.5 V

7/26

73, 74

 

 

operating temperature

 

 

 

 

 

 

 

 

 

 

 

Trouble-shooting:                                      Nominal Value:                       Cause of Fault:

(If nominal value is not attained)

 

A general distinction must be made here between air flow meters with idle CO pot. (5 plug terminals occupied) and without idle CO pot. (4 plug terminals occupied). There are therefore also different terminal assignments, see relevant circuit diagram.

 

· Ignition ON

 

· Remove air flow meter                                            0.1 to 0.3 V                                            · Short circuit of signal lead Ter. 2

plug                                                                                                                                               (signal lead) with Ter. 3 (+)

· Control unit defective

 

· Bridge Ter. 3 (+) with Ter. 2 on                             > 4.2 V                                                   · Lead interruption or short circuit

air flow meter plug using adapter                                                                                            to ground from

cable from KM-609                                                                                                                     - Control unit Ter. 12 (+) to AFM Ter. 3

- Control unit Ter. 7 (signal lead) to

AFM Ter. 2

· Control unit defective

 

· Check voltage between                                          > 4.9 V                                                   · Lead interruption from control unit

Ter. 3 (+) and Ter. 4 (-) on                                                                                                        Ter. 26 (-) to AFM Ter. 4

air flow meter plug with multimeter

 

If nominal values are attained          · Air flow meter electrically defective

 

· Air valve jams (note stress marks)

 

· Carry out noise check

Air flow meter checking values:                                                                                                 (see next page)

Ter. 2 (signal lead)/Ter. 4 (-):                                    8 to 2500 W

Ter. 3 (+)/Ter. 4 (-):                                                     300 to 550 W

 

 

Note:       The terminal designations are located under the rubber grommet of the AFM plug.

 

 

AFM Noise Check

 

Testers: Opel Tester or Multimeter MKM-587-A

 

Test: Adapt air flow meter terminals 2, 3 and 4 with cables from KM-609.

 

Example: Test with Opel Tester

 

- Red checking cable to AFM Ter. 2 (signal lead)

 

- Black checking cable to AFM Ter. 4 (ground)

 

- Tester adjustment: "MULTI", "U", "Spez." (special input), "%", "10V"

 

- Connect black terminal to battery negative terminal

 

- Ignition ON

 

- Open air valve slowly and regularly

 

Nominal Value: 0.17 to 4.9 V and oscilloscope diagram 1

 

AFM is defective if signal corresponds to oscilloscope diagram 2

 

 

Object Number: 2377811  Size: DEFAULT

Object Number: 2377812  Size: DEFAULT

Oscilloscope diagram 1

 

The horizontal line travels up the screen as the air valve opens and then returns to the start position.

Oscilloscope diagram 2

 

If the horizontal line is interrupted or irregular, the AFM is defective.

 

 