vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0: Data List - Test Step 28 PHASE SENSOR > < F0: Data List - Test Step 26 O2 BLOCK LEARN 1

 

 

 

 

 

Test

TECH 1

Notes

Nominal Values

Possible

Step

Display

 

 

Trouble

No.

 

 

 

Codes

 

 

 

 

 

 

 

 

 

 

27

O2 BLOCK LEARN 2

Ignition ON

128 steps

 

 

 

 

 

 

 

 

Engine at idle speed

 

 

 

 

(operating temperature)

 

 

 

 

With open loop systems:

 

 

 

 

20 XE, 20 XEJ

128 steps

44, 45

 

 

 

 

 

 

 

With closed loop systems:

 

 

 

 

C 20 XE

124 to 131 steps

 

 

 

 

 

 

 

 

Note:

 

Via O2 BLOCK LEARN 2, learned multiplicative deviations from the ideal mixture condition (e.g. by alterations in the density of the air, alterations in the density and quality of the fuel, injection valve errors, etc.) are captured by the control unit and stored in the permanent memory.

The learning process takes place only if the oxygen regulation is active and the engine is operating normally.

The multiplicative correction factor operates in the whole characteristic curve range, but dominates mainly in the central to high engine speed ranges. With O2 BLOCK LEARN 2 an evaluation of the learned values of the system can be made.

To evaluate O2 BLOCK LEARN 2, O2 INTEGRATOR must also be consulted.

If O2 BLOCK LEARN 2 continues to display a marginal value (no value change over a considerable period of time), O2 INTEGRATOR must be observed. If this also lies outside the tolerance range, a statement can be made about the mixture condition of the engine.

 

Trouble-shooting:                                 Nominal Value:                       Cause of Fault:

 

For

· O2 BLOCK LEARN 2 < 124 steps                   20 XE, 20 XEJ: 128 steps                   · See test step 25

and                                                                                                                                          System becomes leaner, mixture too rich

· O2 INTEGRATOR < 123 steps                       C 20 XE: 124 to 131 steps

 

· O2 BLOCK LEARN 2 > 131 steps                                                                                  · See test step 25

and                                                                                                                                          System becomes richer, mixture too lean

· O2 INTEGRATOR > 133 steps

 


Related Literature Units
-F0: Data List - Test Step 25 O2 INTEGRATOR
-
-

F0: Data List - Test Step 28 PHASE SENSOR > < F0: Data List - Test Step 26 O2 BLOCK LEARN 1