Trouble
|
Information
Sensor
|
Remedy in
|
Trouble Code
Storage when ...
|
Code
|
Cause of Fault
|
F0:DATA LIST
|
|
|
|
Test Step
|
|
|
|
|
|
|
|
|
|
13
|
O2 SENSOR
|
24
|
The fault is recognised by the
control unit, if
|
|
|
|
·
Over a period t > 2.55 s
|
|
|
|
·
The oxygen sensor voltage is 0.59 > US
> 0.38 V.
|
|
|
|
|
|
|
|
The fault is stored and the
replacement value called up only if the
|
|
|
|
following conditions are
satisfied consecutively:
|
|
|
|
1.)Coolant temperature T > 70 °C/158 °F
(condition 1)
|
|
|
|
2.)Fault for t > 3 mins known,
after condition 1 satisfied (condition 2)
|
|
|
|
3.)Load signal tL > 3.5 ms (condition 3)
|
|
|
|
4.)Conditions 1 to 3 satisfied
simultaneously for t > 5.2 s
|
|
|
|
5.)No storage of trouble codes 73
or 74
|
|
|
|
|
|
|
|
If trouble code 13 is stored, the
control unit takes 450 mV as a
|
|
|
|
replacement voltage
|
|
|
|
|