Ignition
Distributor
Adjusting
Data
Manufacturer Delco-Remy
Code
number 1 103 478 1 103
623 1 103 628 1 111 398
Ignition
timing adjustment Adjustment is made at idle speed.
Ignition markings must align.
Ignition
timing adj. in °CA/rpm 0 to 1/1000 0 to 1/1000 0
to 1/1000 1 to 1/1000
9
to 15/180 9 to 14/1800 9 to 14/1800 5 to 10/1600
26
to 30/4200 18 to 22/4200 18 to 22/4200 22 to 26/4200
Final
adjustm. °CA. 26 to 30 18 to 22 18
to 22 22 to 26
Ignition timing
adjustment with vacuum
Start at
kPa 12 to 17 10 to 14 12 to 17 12
to 17
Finish at
kPa 124,5 to 26 22 to 24 19 to 20 22
to 26
Final adjustm.. °CA. 12,5
to 16,5 12,5 to 16,5 6 to 10 12,5 to 16,5
Dwell angle ° electronic
dwell angle control
Closure time % --
Condensor capacity µF --
Resistance of
ignition lead ohms approx.
20 000 (maximum)
When close interference
resistance of rotor ohms 5000
+ 20%
Resistance of
cable "4" ohms --
Ignition
Distributor
Manufacturer
|
Delco
|
Bosch
|
Code number
|
3 470 271
|
0 231 170 339
|
0 237 021 021
|
0 237 021 025
|
Ignition timing
adjustment
|
Adjustment is made at idle speed. Ignition
markings must align.
|
Ignition
adjustment in
°CA
rpm
Final
adjustment °CA rpm
|
0
to 1/1000
1
to 8/1500
12
to 17/2500
15
to 20/3000
20
to 24/3800
20
to 24
|
0
to 4/1200
7
to 12/1600
18
to 22/3000
18
to 22
|
0
to 1/1000
3
to 12/1400
11
to 15,5/2000
16,5
to 20,5/3000
16
to 20/4000
16,5
to 20,5/3000
15,5 to 19,5/6000
|
Ignition
adjustment with vacuum
Start
at
kPa
at
mbar
Finish
at
kPa
at
mbar
Final adjustment °CA
rpm
|
13
to 17
24,5
to 25,5
12,5 to 16,5
|
120
to 170
250
to 260
6 to 10
|
120
to 195
330
to 350
13 to 15
|
Dwell
angle °
Closure time %
|
47
to 53 at min. 0,4 mm
53 to 59 Electrode gap
|
electronic dwell angle control
-
|
Condensor
capacity mF
|
0,17 to 0,23
|
-
|
Resistance of
ignition lead ohms
|
approx. 20 000 (maximum)
|
When close
interference resistance of rotor ohms
|
5000 + 20%
|
1000
|
Resistance of
cable "4" ohms
|
-
|
approx. 10 000
(maximum)
|
5000 to 8000
|
|
|
|
|
|
|
|
Ignition
Distributor
Adjusting
Data
Manufacturer
|
Bosch
|
Code number
|
0 237 021 023
|
0 237 503 001
|
Ignition timing
adjustment
|
Adjustment is made at idle speed.
Ignition markings must align.
|
Ignition
adjustment in
°CA
rpm
Final
adjustment °CA rpm
|
0
to 3/1400
13
to 17/3200
23
to 25/5000
23
to 25
|
Electronically
controlled.
|
Ignition
adjustment with vacuum
Start
at
kPa
at
mbar
Finish
at
kPa
at
mbar
Final adjustm. °CA
rpm
|
120
to 170
250
to 260
11,5 to 16,5
|
80
to 140
280
to 320
11,5 to 15,5
|
Dwell
angle
Closure time %
|
-
|
Condensor
capacity mF
|
-
|
Resistance of
ignition lead ohms
|
approx. 20 000 (maximum)
|
When close
interference resistance of rotor ohms
|
1000
|
Resistance of
cable "4" ohms
|
5000 - 8000
|
Ignition
Distributor
Adjusting
Data
Manufacturer
|
Bosch
|
Code number
|
0 237 504 002
|
0 237 504 005
|
0 237 504 005
|
Ignition timing
adjustment
|
Adjustment is made at idle speed.
Ignition markings must align.
|
Ignition
adjustment in
°CA
rpm
Final
adjustment °CA rpm
|
Electronically controlled.
|
Ignition
adjustment with vacuum
Start at kPa
Finish at kPa
|
12
to 16 (advance)
20
to 30 (retard)
18
to 20 (advance)
30
to 32 (retard)
|
Final adjustment °CA
rpm
|
6
to 10 (advance)
3 to 7 (retard)
|
12
to 16 (advance)
3 to 7 (retard)
|
Dwell
angle
Closure time %
|
-
|
Condensor
capacity mF
|
-
|
Resistance of
ignition lead ohms
|
approx. 20 000 (maximum)
|
When close
interference resistance of rotor ohms
|
1000
|
Resistance of
cable "4" ohms
|
-
|