Astra
Trouble-shooting: Nominal Value: Cause of Trouble:
Engine idling
· Remove MAP SENSOR 0.1 bar / 0 V · Short circuit between control unit lead plug P 23 K 84/Ter. 22 and plug P 23/Ter. B with lead K 84/Ter. 25 to plug P 23/Ter. C
· Control unit defective
· Short circuit lead Ter. 22 and 0.9 to 1.1 bar / · Short circuit between lead K 84/Ter. 25 Ter. 25 on MAP SENSOR plug 4.7 to 5.1 V and plug P 23/Ter. C or K 84/Ter. 22 Ter. B and C and plug P 23/Ter. B with ground lead K 84/Ter. 13 to plug P 23/Ter. A
Important: When trouble-shooting is finished the control unit Trouble Code memory is to be deleted with TECH 1 in mode F4.
Trouble-shooting: Nominal Value: Cause of Trouble:
· Lead interruption K 84/Ter. 22 to plug P 23/Ter. B · Lead interruption K 84/Ter. 25 to plug P 23/Ter. C · Control unit defective
· Check continuity from plug K 84/Ter. 13 to plug P 23/Ter. A with Multimeter MKM-587-A 0 to 0.2 W · Lead interruption
· Connect Vacuum Pump MKM-667 to See following · MAP SENSOR P 23 defective MAP SENSOR P 23. Adjust vacuum table according to nominal value, turn ignition off and on again after each · Vacuum hose to change in pressure MAP SENSOR P 23 leaking or blocked
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|