|
|
|
|
|
|
Test
|
Tester
|
Checking
|
Notes
|
Nominal
|
Possible Cause of
Trouble,
|
Step
|
Multimeter
|
|
|
Value
|
Trouble-shooting
|
|
MKM-587-A
|
of
|
between
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
Ohmmeter
|
Diagnostic
|
A
|
Ground
|
Ignition
|
approx. 0 W
|
· Transfrer
resistance at
|
|
|
plug
|
|
|
OFF
|
|
grounding point too high
|
|
|
(ALDL): ground
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
Voltmeter
|
Diagnostic
|
B
|
Ground
|
Ignition
|
> 9.0 V
|
· Battery voltage
too low
|
|
Range: 20 V
|
plug (ALDL):
|
|
|
ON
|
|
· Lead interruption
between
|
|
DC
|
excitation lead
|
|
|
|
|
X 13/Ter.B and X 5/Ter. 5
|
|
|
|
|
|
|
|
· Lead interruption
between
|
|
|
|
|
|
|
|
X 5/Ter. 5 and K 84/Ter. 20
|
|
|
|
|
|
|
|
· Control unit K 84
defective
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3
|
Voltmeter
|
Diagnostic
|
F
|
Ground
|
Ignition
|
> 11.5 V
|
· Battery voltage
too low
|
|
Range: 20 V
|
plug
|
|
|
ON
|
|
· Lead interruption
between
|
|
DC
|
(ALDL): voltage
|
|
|
|
|
X 13/Ter. F and voltage supply
|
|
|
supply Ter. 30
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4
|
Voltmeter
|
Diagnostic
|
G
|
Ground
|
Ignition
|
0 to 0.2 V
|
· Battery voltage
too low
|
|
Range: 20 V
|
plug
|
|
|
ON
|
|
· Lead interruption
between
|
|
DC
|
(ALDL):
|
|
|
|
|
X 13/Ter. G and X 5/Ter. 4
|
|
|
data lead
|
|
|
|
|
· Lead interruption
between
|
|
|
|
|
|
|
|
X15/Ter. 4 and K 84/Ter. 19
|
|
|
|
|
|
|
|
· Control unit K 84
defective
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5
|
-
|
Telltale H 30
|
-
|
-
|
Ignition
|
Telltale H
|
0·Telltale H 30
defective
|
|
|
|
|
|
ON
|
ON
|
· Lead interruption
between
|
|
|
|
|
|
|
|
H 30 and X 21/Ter. 12
|
|
|
|
|
|
|
|
· Lead interruption
between
|
|
|
|
|
|
|
|
X 21/Ter. 12 and X 5/Ter. 11
|
|
|
|
|
|
|
|
· Lead interruption
between
|
|
|
|
|
|
|
|
X 5/Ter. 11 and K 84/Ter. 16
|
|
|
|
|
|
|
|
· Control unit K 84
defective
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
-
|
TECH 1
|
-
|
-
|
See
|
-
|
-
|
|
|
self-test
|
|
|
TECH 1
|
|
|
|
|
|
|
|
Operating
|
|
|
|
|
|
|
|
Instructions
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: After Test Steps 7
and 8 any Trouble Codes which may be stored are deleted.
|
|
|
|
|
|
|
|
|
|
|
7
|
Ohmmeter
|
Plug on
|
5
|
Ground
|
Ign. OFF
|
approx. 0 W
|
· Transfer
resistance at
|
|
|
control unit
|
|
|
Disconnect
|
|
grounding point too high
|
|
|
K 84: ground
|
|
|
plug on
|
|
· Lead interruption
between
|
|
|
|
|
|
control unit
|
|
K 84/Ter. 5 and grounding point
|
|
|
|
|
|
K 84
|
|
· Control unit K 91
defective
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8
|
Voltmeter
|
Plug on control
|
|
|
Ign. OFF
|
> 11.5 V
|
· Battery voltage
too low
|
|
Range: 20 V
|
unit K 84:
|
|
|
Remove plug
|
|
· Lead interruption
between
|
|
DC
|
voltage
|
|
|
on control
|
|
K 84/Ter. 12 and Ter. 30
|
|
|
supply
|
|
|
unit K 84
|
|
· Lead interruption
between
|
|
|
Ter. 30:
|
12
|
Ground
|
Ign. ON
|
|
K 84/Ter. 09 and Ter. 15
|
|
|
Ter. 15:
|
9
|
|
|
|
Control unit K 84 defective
|
|
|
|
|
|
|
|
|