Trouble
Information Sensor
Remedy in
Trouble Code Storage when ...
Code
Cause of Fault
F0:DATA LIST
Test Step
46
Oil temperature sensor
· Oil temperature > 140 °C/284 °F (< 0.5 V)
Voltage too low
02
If Trouble Code 46 is stored, the control
unit carries out no temperature adjustment.