Automatic
Transmission AF 22:
· At Ter. 15 the
transmission control unit recognizes no pulse width modulated signal
(frequency 122 Hz) or one which is outside of the permitted range;
the Low level (less than 0.1 V) of the PWM signal occurs for
less than 0.15 ms or for longer than 9.3 ms;
(invalid pulse width or frequency)
· The above conditions must
be fulfilled for at least 4 s
If trouble
code 74 was recognized, the fault is stored but the emergency program is not
activated.
|