vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Compression 3-cylinder, Unsynchronised > < Battery / Starter, Petrol (Current Measurement)

Battery / Starter (Voltage Measurement)

 

Objective:

Evaluation of the state of charge of the battery, voltage supply to the starter during starting and operation of the starter.

Measurement:

Plot of the battery voltage during the start procedure.

Preparation:

Switch off the engine, switch off the ignition, switch off all electrical loads.

Connections:

INPUT A

COM/TRIGGER

INPUT B

Connect the red measurement lead to the positive pole of the battery. Connect the black measurement lead to the negative pole of the battery.

 

 


Procedure Tech 31:

1. Download Reference curve.
2. Start engine.

Reference Curve:

Object Number: 2400929  Size: DEFAULT

Procedure Tech 32:

1. Download Setup file (the Tech 32 uses only Setup files, no reference curves).
2. Start engine.

Setup File:

Reference Curve:

Object Number: 2419066  Size: DEFAULT

Compression 3-cylinder, Unsynchronised > < Battery / Starter, Petrol (Current Measurement)