vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Pressure accumulator > < Solenoid Valve For Charge Pressure Control, Replace (Z 17 DTH, With Air Conditioning, LHD)

Solenoid Valves, Changeover Valves, Intake Manifold, Replace (Z 17 DTH, With Air Conditioning, LHD)

  Remove

1.   Open bonnet
2.   Raise vehicle
3.   Remove solenoid valve (1)
•   Remove 2x vacuum hose
•   Disconnect wiring harness plug
•   Loosen lower bolt
•   Unscrew upper bolt
4.   Lower vehicle
Object Number: 2408145  Size: DEFAULT


  Install

5.   Install solenoid valve
•   Tighten 2 bolts 6.9 Nm
•   Connect wiring harness plug
•   Connect 2x vacuum hose
6.   Close bonnet