Connect the bleeding device to brake bleeder adapter (1). Only
use DOT 4 brake fluid. Pressurise brake system (2) – note
manufacturer's information. Leave the relevant bleeder screw (3)
open until clear, bubble-free brake fluid flows out. Bleed at all
four bleeder screws, do no re-use the effluent brake fluid. Tighten
bleeder screw – tightening torque 9 Nm / 6.6 lbf. ft.
Remove bleeding device. (Note residual pressure in the
brake-fluid reservoir). Top up brake-fluid level up to the marking
"MAX" and screw lid. Check brake system for leaks – see
operation "Brake System, Check for Leaks".
Note: If extremely
long brake travel and low brake efficiency are established during
the test drive (vehicles with ABS), repeat the bleeding procedure
and simultaneously actuate the return pump via Tech 1 or Tech
2.
|