Trouble-shooting
|
Nominal Value
|
Cause of
Fault:
(If nominal
value is not attained)
|
· Ignition OFF
· Disconnect wiring harness
plug from DDE control unit K70
· Disconnect wiring harness
plug from AT control unit K85
· Ignition ON
· Using multimeter, measure
voltage
from: wiring harness plug for DDE control unit K70 Ter. 43
to: ground
|
lower than 0.1 V
|
· Short circuit to voltage
from: wiring harness plug for DDE control unit K70 Ter. 43
to: wiring harness plug for automatic transmission K85
Ter. 4
|
|
|
|
· Ignition OFF
· Using multimeter, measure
resistance
from: wiring harness plug for DDE control unit K70 Ter. 43
to: ground
|
greater than 100 kW (¥)
|
· Short circuit to ground
from: wiring harness plug for DDE control unit K70 Ter. 43
to: wiring harness plug for automatic transmission control
unit K85 Ter. 4
|
|
|
|
· Using multimeter, measure
resistance
from: wiring harness plug for DDE control unit K70 Ter. 43
to: wiring harness plug for automatic transmission control
unit K85 Ter. 4
|
lower than 2 W
|
· Circuit interruption
from: wiring harness plug for DDE control unit K70 Ter. 43
to: wiring harness plug for automatic transmission control
unit K85 Ter. 4
|
|
|
|
|
If nominal values are attained
|
· DDE control unit K70
defective
or
· Automatic transmission
control unit K85 defective
|
|
|
|
|
|
Note:
Before replacing the control unit, check the automatic
transmission control unit for function (see Checking Procedures for
Electronic 4-speed Automatic Transmission).
|
|
|
|