vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F5: ACTUATOR TEST - No. 07 SELECT ACTUATOR EGR PULS.RATIO > < F5: ACTUATOR TEST - No. 05 SELECT ACTUATOR FUEL TANK VENT

F5: ACTUATOR TEST

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

06

 

SELECT ACTUATOR

A / C CUTOFF REL

 

 

 

Vehicles with AC:

 

This check can be performed in two operating  conditions: "ignition ON, engine OFF" and "engine  running at idle speed".

Carry out check 1 if the engine does not start;  otherwise proceed to check 2

 

87, 88

 

25, 19

06

 

 

 

SELECT ACTUATOR

A / C CUTOFF REL

 

 

 

Check l:

 

Ignition ON

 

Engine OFF

 

AC switch ON

 

 

87, 88

25, 19

 

 

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display.

 

Note:

After this check is started, the AC cutoff relay is actuated at a frequency of 0.5 Hz.

The check is completed after a maximum of 30 s.

 

A / C CUTOFF REL switches alternately INACTIVE

        12V

ACTIVE   0V

clicking noise from relay

 

 

06

 

SELECT ACTUAT OR

A / C CUTOFF REL

 

Check 2:

 

Engine running at idle speed

 

AC switch ON

 

 

-

25, 24

 

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display.

 

Note:

After this check is started, the AC cutoff relay is actuated at a frequency of 0.5 Hz.

The check is completed after a maximum of 30 s.

The AC cutoff relay switches at a frequency of 0.5 Hz alternately INACTIVE 12V ACTIVE 0V AC compressor switches ON and OFF

 

 

Notes on Trouble - shooting:

Nominal Value:

Cause of Fault:

X 20 SE engine only:

·   Ignition OFF

·   Disconnect AC cutoff relay

·   Disconnect control unit K 61 from wiring harness

·   Check from AC cutoff unit relay base K 60 / Ter. 6 to control unit K 61 / Ter. 25 for passage

approx. 0 W

·   Short circuit or lead interruption from control unit K 61 / Ter. 25 to AC cutoff relay base K 60 / Ter. 6

·   AC cutoff relay K 60 defective

·   AC conditioning defective

·   Control unit K 61 defective

 

 

 


Related Literature Units
-TABLE 2, TROUBLE CODES - Trouble Code 87 A/C CUTOFF RELAY VOLTAGE LOW
-

F5: ACTUATOR TEST - No. 07 SELECT ACTUATOR EGR PULS.RATIO > < F5: ACTUATOR TEST - No. 05 SELECT ACTUATOR FUEL TANK VENT