· X 20 SE engine only:
· Coolant temperature lower than 125 °C /
257 °F
· Intake air temperature lower than 30 °C
/ 68 °F
· Trouble codes 73 and 74 not recognized
· Engine load signal greater than 1.3 ms
· Oxygen sensor integrator (internal
control unit value for evaluation of oxygen sensor regulation) has exceeded
upper limit of 1.2 (mixture constantly too lean)
· Conditions must be fulfilled for at
least 10 s
|