F0: DATA LIST
No.
|
TECH 1-Display
|
Conditions
for Checking
|
Nominal
Value
|
Trouble
Codes
|
Terminal
|
27
|
INT.
MANIFOLD V.1
|
Engine running at idle speed,
operating temperature
|
INACTIVE 12V
|
59,
63, 123
|
6,
24
|
|
|
Depress accelerator pedal
briefly to full load stop
Note:
In this test, the engine must
run for a few seconds at idle speed before the accelerator pedal is actuated
quickly to the full load stop.
|
ACTIVE 0 V
|
|
|
|
|
|
|
|
|
|